Main functions
Operating ambient temperatures
The internal unit of the BreezeleSS + series has TwinFlap double deflectors (louvers) with an air vent and 7928 mini-holes for uniform dispersion of cool air. In addition, BreezeleSS + is considered the first split-conditioner with side air vents. These S-shaped sockets are specifically designed to work with front louvers to ensure optimum air flow through the heat exchanger and improve dispersion.
In the outdoor design unit "Diamond" there is a high-quality DC-inverter compressor running on ozone-safe R32 freon, which is capable of reaching a rotor speed of 65 Hz for 6 seconds, in combination with a high speed of a DC-inverter fan and a wide 70-mm air outlet, can reduce the air temperature in the room in the shortest possible period of time.
This series has successfully passed tests for compliance with a number of technical parameters, according to Eurovent standards. This fact confirms the high quality of products and full compliance with the expectations of customers around the world, as the company produces air conditioners for all major global markets, offers sales and service support through its distribution network on all continents. Only the most famous and popular global manufacturers of air conditioners provided their products for certification in the Eurovent laboratory, which carefully analyze a whole range of characteristics and conduct critical test sets for compliance with the device parameters declared by the plant.
Energy Efficiency
Technology
3D Air Flow
The unit has auto horizontal swing and auto vertical swing function, which supplies more even and comfortable air flow.
5 Grades Outdoor Fan Speeds
By utilising DC fan motors on the outdoor unit, has upgraded the fan speeds from 2 speeds to 5 speeds. This also too contributes to energy saving and again, more control over outdoor fan airflow- generated sound levels.
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Cleaning
Active Clean technology washes away dust, mold and grease that can cause odor as they adhere to the heat exchanger, automatically freezing and then quickly defrosting the frost, warming up the heat exchanger. After that, the impeller continues to work in order to dry out the heat exchanger completely.
When this function is enabled, “CL” is displayed on the display of the indoor unit, after 20–45 minutes, the unit will automatically turn off and itself will cancel the active cleaning function.
To carry out cleaning in the future, you must re-enable this function.
Golden Fin
Gold plating fin heat exchanger - Corrosion protection. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment.
Silence
The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.
TwinFlap
TwinFlap - Absolutely new airflow. Two oppositely movable louvers may evolutionally deflect, and even block the air flow to soften the effect of the draft and the wind from the air flow, providing multiple levels of softness without feeling the wind.
Vector airflow
The latest aerodynamic research has allowed to optimize the design of the air path, and in combination with high performance of the fan, the OP air conditioner can create a powerful directional air beam that will evenly cool (or warm) even the most remote places in the room. At the same time, excellent noise characteristics are provided - 16dB at low speed
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Wi-Fi Control (Wi-Fi stick)
Mission's Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick - option).
Customers can download absolutely free app for your smartphone with the QR-code located in the user's manual.
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
Ozone-friendly freon R32
The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Maintaining temperature +8°С
Protection against freezing of the room, maintaining the temperature of +8°C.
The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.
Crankcase Heater
To prevent the compressor's hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.
The heater of the outdoor unit pallet
The heater of the outdoor unit pallet is installed to ensure complete removal of water from the heat exchanger of the outdoor unit resulting from defrost during the defrosting operation.
Wind Sprayer
An additional airflow divider located behind the main blinds ensures, when activated by the user, a smooth and flooring air flow in the room, excluding the formation of the "draft" effect and supercooling of closely located people.
Eco mode
Economy mode(Eco-mode).Conditioning supports indoor air temperature +24°C with minimum noise and power consumption.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Turbo
Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.
Follow Me
"Follow Me" feature
When this function is enabled on the remote control, the control unit of the indoor unit will receive data about the temperature in the room from the temperature sensor installed in the remote control, which allows you to more precisely control the operation of the air conditioner, reaching the set mode in the area where the remote control is in the room. The range of the signal from the console does not exceed 8 m. in a straight line "remote - indoor unit".
Temperature compensation
The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Inverter Quattro
The technology "Inverter Quattro" includes:
- Flash Cooling/Heating.
- GA Stepless Comfort Technology.
- iECO/Gear Energi Saving.
- High-Ambient Cooling/Low-Ambient Heating.
Gear Control
Using the "Gear Control" function, you can adjust the electricity consumption of the air conditioner by forcing the value in 50%, 75% or 100% of the power.
Limiting the capacity of the system will save energy and "fit" into the limit of power consumption, if necessary.
Wide angle air flow
The vertical louvers of Midea air conditioners swing at an angle of 110° (ordinary air conditioners only swing at 80°), while the horizontal louvers swing at 120° (ordinary air conditioners only swing at 90°). These more flexible louvers provide cooling which is wider and more even.
Specifications
The Indoor Unit
Power, kW
Power consumption, kW
Energy Efficiency Class
Energy Efficiency Ratio
Dimensions(WxHxD), mm
Weight, kg
The outdoor Unit
Freon
Diameter Pipes, mm
Dimensions(WxHxD), mm
Weight, kg
Video
Midea BreezeleSS+ Air Conditioner
The latest progressive series of household split systems Midea BreezeleSS + on the new ozone-safe R32 freon. In the air conditioners of the Midea BreezeleSS + series, the developers used three unique developments designated by three S: Speed (speed), Soft (comfort), Surround (volumetric coolness). The cooling rate is ensured by the ultra-high frequency of the compressor, the high speed of the fan and the wide (70 mm) perforated nanoholes of the indoor unit louver. All this allows the BreezeleSS + conditioner to reduce the indoor temperature in 40 seconds. The indoor unit provides increased user comfort due to the special design of the deflector (blinds), and this is the main distinguishing feature of this model. The air in the room is fed through 7928 holes in the shape of an hourglass at different angles. They simultaneously expand the air flow, accelerate and break it into trickles, making it incredibly enjoyable. BreezeleSS + reverses the concept of air conditioning, turning the cooling process into a unique sensation. In addition, BreezeleSS + is the first air conditioner that additionally supplies air from the side surfaces of the unit, thus cooling the room faster and more evenly.
Soft Midea AIR Setup Wi-Fi
Soft Midea AIR Setup Wi-Fi