Midea MA-24N1D0-I /MA-24N1D0-O (2018) air conditioner (Archived model split systems)

Suggested retail price

0,-hrv.

Main functions

Midea AC 1W Standby feature
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Cooling-Heating
Easy to clean panel
Effective drainage
Follow Me
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Timer
Turbo mode
WiFi Module
Wired Remote Control

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 30 °C

Eurovent certified2017 g model line of Midea equipment, namely the split-system series Blanc, Mission, Ultimate Comfort, Oasis Plus have successfully passed the test for compliance with a number of technical parameters, according to Eurovent standards.

This fact confirms the high quality of the products and full compliance with the expectations of customers all over the world, as the company produces air conditioners for all major world markets, offers sales and service support through its distribution network on all continents. Only the most famous and popular world manufacturers of air conditioners provided their products for certification in the laboratory Eurovent, which carefully analyze a range of characteristics and conduct critical test kits for compliance with the declared factory parameters of devices.

Data on products certified by Eurovent are available for viewing on the Internet at: www.eurovent-certification.com

    Technology

    The Ionizer

    Air purification system is provided with a high-efficiency air conditioner ionizer that produces millions of negative ions that neutralize all the harmful elements present in your home. Negatively charged ions attract the dust particles, bacteria, mold spores and viruses, neutralize them, supporting chichtotu and freshness of the air in the room.

    The ionizer is usually located on the left side of the housing of the indoor unit under the blinds (see photo below). On some series of domestic and semi-industrial split systems, it can be installed optionally)

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Outdoor unit design "Brilliant"

    Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Self-Cleaning

    Self-cleaning mode.

    Depending on the series of the air conditioner, this mode can be activated:

    • automatically (after a one-time activation from the remote control), each time the air conditioner is turned off (at the same time, the blinds on the indoor unit are closed, but the fan continues to work for another 10 ~ 20 minutes, ventilating and drying the heat exchanger).
    • forcibly, every time you activate it from the remote control.

    Note: Check the algorithm of the mode in the user manual.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Indoor Unit

    Model Name
    MA-24N1D0-I
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    2.670
    ... 7.880
    Heating Capacity
    1.610
    ... 8.790

    Power consumption, kW

    Cooling
    0.240
    ... 3.030
    Heating
    0.260
    ... 3.140

    Energy Efficiency Class

    Cooling
    A++
    Heating
    при +2°С=A+++. при -10°C=A++

    Energy Efficiency Ratio

    SEER (cooling mode)
    6.10
    SCOP (heating mode)
    5.10
    ... 4.00
    Air flow rate, m³/h
    1,000
    ... 650
    Sound Pressure Level, dB(A)
    46.50
    ... 28.00
    Sound Power Level, dB(A)
    61.00

    Dimensions(WxHxD), mm

    Without Package
    1038
    x 325
    x 220
    in Multiples
    1120
    x 405
    x 330

    Weight, kg

    Net Weight
    12.00
    Gross Weight
    15.00

    The outdoor Unit

    Model Name
    MA-24N1D0-O
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY

    Freon

    Freon Type
    R410A
    Freon Weight, kg
    1.85, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    2,700
    Sound Pressure Level, dB(A)
    60.00
    Sound Power Level, dB(A)
    66.00

    Diameter Pipes, mm

    Liquid
    9.52
    Gas
    15.90
    Max length of main line, m
    50
    Max vertical drop, m
    25

    Dimensions(WxHxD), mm

    Without Package
    845
    x 702
    x 363
    in Multiples
    965
    x 755
    x 395

    Weight, kg

    Net Weight
    49.00
    Gross Weight
    52.00