Midea AF-09N1C2B-I /AF-09N1C2B-O (2021) air conditioner (Archived model split systems)

Suggested retail price

0,-hrv.

Main functions

2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Cleaning
Cooling-Heating
Easy to clean panel
Effective drainage
Follow Me
IR Remote Control
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Turbo mode
Carbon air filter
The central group control panel
WiFi Module
Wired Remote Control
Carbon air filter
Silver Ion filter

Operating ambient temperatures

Cooling mode
0
... + 50 °C
Heating mode
- 15
... + 30 °C
    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Cleaning

    Active Clean technology washes away dust, mold and grease that can cause odor as they adhere to the heat exchanger, automatically freezing and then quickly defrosting the frost, warming up the heat exchanger. After that, the impeller continues to work in order to dry out the heat exchanger completely.
    When this function is enabled, “CL” is displayed on the display of the indoor unit, after 20–45 minutes, the unit will automatically turn off and itself will cancel the active cleaning function.
    To carry out cleaning in the future, you must re-enable this function.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Maintaining temperature +8°С

    Protection against freezing of the room, maintaining the temperature of +8°C.

    The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Follow Me

    "Follow Me" feature

    When this function is enabled on the remote control, the control unit of the indoor unit will receive data about the temperature in the room from the temperature sensor installed in the remote control, which allows you to more precisely control the operation of the air conditioner, reaching the set mode in the area where the remote control is in the room. The range of the signal from the console does not exceed 8 m. in a straight line "remote - indoor unit".

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    The Indoor Unit

    Model Name
    AF-09N1C2B-I
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    1.180
    ... 3.230
    Heating Capacity
    0.910
    ... 3.760

    Power consumption, kW

    Cooling
    0.100
    ... 1.250
    Heating
    0.140
    ... 1.340

    Energy Efficiency Class

    Cooling
    A
    Heating
    A

    Energy Efficiency Ratio

    SEER (cooling mode)
    5.10
    SCOP (heating mode)
    3.40
    EER (сooling mode)
    3.21
    COP (heating mode)
    3.61
    Air flow rate, m³/h
    417
    ... 256
    Sound Pressure Level, dB(A)
    36.50
    ... 24.00

    Dimensions(WxHxD), mm

    Without Package
    715
    x 319
    x 256
    in Multiples
    780
    x 365
    x 270

    Weight, kg

    Net Weight
    7.50
    Gross Weight
    9.50

    The outdoor Unit

    Model Name
    AF-09N1C2B-O
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R410
    Freon Weight, kg
    0.59, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    1,800
    Sound Pressure Level, dB(A)
    55.50

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    9.52
    Min length of main line, m
    3
    Max length of main line, m
    25
    Max vertical drop, m
    10

    Dimensions(WxHxD), mm

    Without Package
    720
    x 495
    x 270
    in Multiples
    835
    x 540
    x 300

    Weight, kg

    Net Weight
    22.80
    Gross Weight
    24.80