Midea AURORA MSAB-09HRFN8-I /MSAB-09HRFN8-O air conditioner

Suggested retail price

24 320,-hrv.

Main functions

Midea AC 1W Standby feature
2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Chassis Heating Belt
Cleaning
Cooling-Heating
Easy to clean panel
Effective drainage
Follow Me
IR Remote Control
LED display
Louver Position Memory Function
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
High Density filter
The central group control panel
WiFi Module
Wired Remote Control
Carbon air filter

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 27
... + 30 °C

Operation temperature Indoor

Cooling mode
+ 17
... + 32 °C
Heating mode
0
... + 30 °C
  • The Aurora series split system has a high level of energy efficiency thanks to the GMCC inverter compressor, inverter motors for the fans of the outdoor and indoor units.
  • The air conditioner supports the function of protecting your home from hypothermia (+8°C).
  • The high-density anti-dust air filter cleans the air well and protects the indoor unit from dust, pollen and other all kinds of particles.
  • The self-cleaning system of the indoor unit allows you to protect the heat exchanger from the appearance of bacteria and mold on it.
  • In night mode, the display and sound signals are turned off, while the noise level of the indoor unit is reduced to 20 dB.
  • The standard equipment includes a modern IR remote control.
    Technology

    Cleaning

    Active Clean technology washes away dust, mold and grease that can cause odor as they adhere to the heat exchanger, automatically freezing and then quickly defrosting the frost, warming up the heat exchanger. After that, the impeller continues to work in order to dry out the heat exchanger completely.
    When this function is enabled, “CL” is displayed on the display of the indoor unit, after 20–45 minutes, the unit will automatically turn off and itself will cancel the active cleaning function.
    To carry out cleaning in the future, you must re-enable this function.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Crankcase Heater

    To prevent the compressor's hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Follow Me

    "Follow Me" feature

    When this function is enabled on the remote control, the control unit of the indoor unit will receive data about the temperature in the room from the temperature sensor installed in the remote control, which allows you to more precisely control the operation of the air conditioner, reaching the set mode in the area where the remote control is in the room. The range of the signal from the console does not exceed 8 m. in a straight line "remote - indoor unit".

    Golden Fin

    Gold plating fin heat exchanger - Corrosion protection. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Maintaining temperature +8°С

    Protection against freezing of the room, maintaining the temperature of +8°C.

    The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Outdoor unit design "Brilliant"

    Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

    Ozone-friendly freon R32

    The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Silence

    The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Indoor Unit

    Model Name
    MSAB-09HRFN8-I
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    1.030
    ... 3.220
    Heating Capacity
    0.820
    ... 3.370

    Power consumption, kW

    Cooling
    0.090
    ... 1.140
    Heating
    0.110
    ... 1.080

    Energy Efficiency Class

    Cooling
    A+++
    Heating
    при +2°С A+++, при -7°С A++, при -10°С А

    Energy Efficiency Ratio

    SEER (cooling mode)
    9.30
    SCOP (heating mode)
    6.00
    ... 3.60
    Air flow rate, m³/h
    483
    ... 303
    Sound Pressure Level, dB(A)
    36.50
    ... 24.00
    Sound Power Level, dB(A)
    55.00

    Dimensions(WxHxD), mm

    Without Package
    802
    x 297
    x 189
    in Multiples
    875
    x 380
    x 285

    Weight, kg

    Net Weight
    8.60
    Gross Weight
    11.10

    The outdoor Unit

    Model Name
    MSAB-09HRFN8-O
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R32
    Freon Weight, kg
    0.62, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    2,150
    Sound Pressure Level, dB(A)
    54.00
    Sound Power Level, dB(A)
    60.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    9.52
    Min length of main line, m
    3
    Max length of main line, m
    25
    Max vertical drop, m
    10

    Dimensions(WxHxD), mm

    Without Package
    765
    x 555
    x 303
    in Multiples
    887
    x 610
    x 337

    Weight, kg

    Net Weight
    26.40
    Gross Weight
    28.80