Midea Forest DC AF6-09N1C2-I /AF6-09N1C2-O air conditioner

Suggested retail price

17 900,-hrv.

Main functions

2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Cleaning
Cooling-Heating
Easy to clean panel
Effective drainage
Follow Me
IR Remote Control
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Turbo mode
Carbon air filter
The central group control panel
WiFi Module
Wired Remote Control
Carbon air filter
Silver Ion filter

Operating ambient temperatures

Cooling mode
0
... + 50 °C
Heating mode
- 15
... + 24 °C

Operation temperature Indoor

Cooling mode
+ 17
... + 32 °C
Heating mode
0
... + 30 °C

The Forest series of air conditioners has a classic, elegant design of an indoor unit with a hidden LED display and the ability to install a WI-FI module (optional), a modern stylish IR remote control, an outdoor unit with an energy-efficient GMCC inverter compressor.

• Self-diagnosis
• Temperature support +8°С (when operating in heating mode)
• Hydrophilic coating of heat exchangers
• Auto restart
• Comfortable sleep mode
• TURBO function
• Anti-corrosion coating
• Wi-Fi (optional)
• Memorizing the position of the blinds
• Timer

    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Cleaning

    Active Clean technology washes away dust, mold and grease that can cause odor as they adhere to the heat exchanger, automatically freezing and then quickly defrosting the frost, warming up the heat exchanger. After that, the impeller continues to work in order to dry out the heat exchanger completely.
    When this function is enabled, “CL” is displayed on the display of the indoor unit, after 20–45 minutes, the unit will automatically turn off and itself will cancel the active cleaning function.
    To carry out cleaning in the future, you must re-enable this function.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Maintaining temperature +8°С

    Protection against freezing of the room, maintaining the temperature of +8°C.

    The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Indoor Unit

    Model Name
    AF6-09N1C2-I
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    1.180
    ... 3.230
    Heating Capacity
    0.910
    ... 3.760

    Power consumption, kW

    Cooling
    0.100
    ... 1.250
    Heating
    0.140
    ... 1.340

    Energy Efficiency Class

    Cooling
    A
    Heating
    A

    Energy Efficiency Ratio

    SEER (cooling mode)
    5.10
    SCOP (heating mode)
    3.40
    EER (сooling mode)
    3.21
    COP (heating mode)
    3.61
    Air flow rate, m³/h
    417
    ... 256
    Sound Pressure Level, dB(A)
    36.50
    ... 24.00

    Dimensions(WxHxD), mm

    Without Package
    715
    x 285
    x 194
    in Multiples
    780
    x 365
    x 270

    Weight, kg

    Net Weight
    7.50
    Gross Weight
    9.50

    The outdoor Unit

    Model Name
    AF6-09N1C2-O
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R410A
    Freon Weight, kg
    0.59, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    1,800
    Sound Pressure Level, dB(A)
    55.50

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    9.52
    Min length of main line, m
    3
    Max length of main line, m
    25
    Max vertical drop, m
    10

    Dimensions(WxHxD), mm

    Without Package
    720
    x 495
    x 270
    in Multiples
    835
    x 540
    x 300

    Weight, kg

    Net Weight
    22.80
    Gross Weight
    24.80