Діапазон робочих зовнішніх температур
Рекомендована ціна
Характеристики
| HP | 7 | 8 | 9 | ||||
| Model name | MVi-200WV2RN1(A) | MVi-224WV2RN1(A) | MVi-260WV2RN1(A) | ||||
| Power supply | V/Ph/Hz | 380-415/3/50 | |||||
| Cooling1 | Capacity | kW | 20 | 22.4 | 26.0 | ||
| Power input | kW | 5.28 | 6.77 | 10.04 | |||
| EER | 3.79 | 3.31 | 2.59 | ||||
| Heating2 (Rated) |
Capacity | kW | 20 | 22.4 | 26.0 | ||
| Power input | kW | 4.43 | 5.42 | 6.86 | |||
| COP | 4.51 | 4.13 | 3.79 | ||||
| Heating3 (Max.) | Capacity | kW | 22.5 | 25.0 | 28.5 | ||
| Power input | kW | 5.95 | 6.67 | 7.70 | |||
| COP | 3.78 | 3.75 | 3.70 | ||||
| Connected indoor unit |
Total capacity | 50-130% of outdoor unit capacity | |||||
| Maximum quantity | 11 | 13 | 15 | ||||
| Compressor | Type | DC inverter rotary | |||||
| Quantity | 1 | ||||||
| Oil type | RB75EA | ||||||
| Start-up method | Soft start | ||||||
| Fan | Type | Propeller | |||||
| Motor type | DC | ||||||
| Quantity | 2 | ||||||
| Motor output | kW | 0.17×2 | 0.17×2 | 0.17×2 | |||
| Air flow rate | m3/h | 9000 | 9000 | 10000 | |||
| Drive type | Direct | ||||||
| Refrigerant | Type | R410A | |||||
| Factory charge | kg | 6.5 | 6.5 | 6.5 | |||
| Pipe connections4 |
Liquid pipe | mm | Ф9.53 | Ф9.53 | Ф9.53 | ||
| Gas pipe | mm | Ф19.1 | Ф19.1 | Ф22.2 | |||
| Sound pressure level5 | dB(A) | 58 | 58 | 59 | |||
| Sound power level5 | dB(A) | 78 | 78 | 78 | |||
| Net dimensions (W×H×D) | mm | 1120×1558×528 | |||||
| Packed dimensions (W×H×D) | mm | 1270×1720×565 | |||||
| Net weight | kg | 143 | 143 | 144 | |||
| Gross weight | kg | 159 | 159 | 160 | |||
| Ambient Temp. operation range |
Cooling | oC | -5~48 | ||||
| Heating | oC | -20~24 | |||||
| Notes: | |||||||
| 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 4. Diameters given are those of the unit's stop valves. | |||||||
| 5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber. | |||||||
| HP | 10 | 12 | |||||
| Model name | MVi-280WV2RN1(A) | MVi-335WV2RN1(A) | |||||
| Power supply | V/Ph/Hz | 380-415/3/50 | |||||
| Cooling1 | Capacity | kW | 28.5 | 33.5 | |||
| Power input | kW | 12.23 | 15.30 | ||||
| EER | 2.33 | 2.19 | |||||
| Heating2 (Rated) | Capacity | kW | 28.5 | 33.5 | |||
| Power input | kW | 7.68 | 10.15 | ||||
| COP | 3.71 | 3.30 | |||||
| Heating3 (Max.) | Capacity | kW | 31.5 | 37.5 | |||
| Power input | kW | 7.87 | 11.72 | ||||
| COP | 4.00 | 3.20 | |||||
| Connected indoor unit |
Total capacity | 50-130% of outdoor unit capacity | |||||
| Maximum quantity | 16 | 20 | |||||
| Compressor | Type | DC inverter rotary | |||||
| Quantity | 1 | 1 | |||||
| Oil type | RB75EA | FV50S | |||||
| Start-up method | Soft start | ||||||
| Fan | Type | Propeller | |||||
| Motor type | DC | ||||||
| Quantity | 2 | ||||||
| Motor output | kW | 0.17×2 | 0.17×2 | ||||
| Air flow rate | m3/h | 11000 | 11300 | ||||
| Drive type | Direct | ||||||
| Refrigerant | Type | R410A | |||||
| Factory charge | kg | 6.5 | 8 | ||||
| Pipe connections4 | Liquid pipe | mm | Φ9.53 | Φ12.7 | |||
| Gas pipe | mm | Φ22.2 | Φ25.4 | ||||
| Sound pressure level5 | dB(A) | 60 | 61 | ||||
| Sound power level5 | dB(A) | 78 | 81 | ||||
| Net dimensions (W×H×D) | mm | 1120×1558×528 | |||||
| Packed dimensions (W×H×D) | mm | 1270×1720×565 | |||||
| Net weight | kg | 144 | 157 | ||||
| Gross weight | kg | 160 | 173 | ||||
| Ambient Temp. operation range | Cooling | oC | -5~48 | ||||
| Heating | oC | -20~24 | |||||
| Notes: | |||||||
| 1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
| 4. Diameters given are those of the unit's stop valves. | |||||||
| 5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber. | |||||||
Технологія
Sine-Wave Inverter
Технологія 180° -градусного хвильового инверторного перетворення - керуюча напруга без «імпульсних» ефектів (усувається ступенчатость синусоїди).
У порівнянні з стандартним 120° струмом прямокутної форми надає наступні переваги:
- Можливість роботи при більш широкому діапазоні живлячої напруги і частоти струму.
- Велику енергоефективність та енергозбереження.
- Більш м'який старт, нижче шум і вібрації.
- Великі можливості управління.
Алюмінієвий теплообмінник з гідрофільним покриттям
Підвищена змочуваність теплообмінника, алюмінієві пластини якого мають спеціальне покриття з гідрофільним шаром, що забезпечує швидке видалення конденсату з внутрішнього блоку, що не дозволяє швидко утворюватися цвілі і бактерій, забезпечуючи при цьому більш ефективну роботу кондиціонера.
Компресор DC inverter
Компресор з інвертором постійного струму дозволяє збільшити ефективність роботи кондиціонера, таким чином, зниження споживання енергії заощаджує Ваші витрати. Така система значно економніше та надійніше, ніж кондиціонери з постійною потужністю компресора.
Мотор DC inverter зовнішнього блоку
У зовнішніх блоках для обертання вентилятора використовується DC-мотор. Це дозволяє значно знизити рівень шуму та енергоспоживання, а так же отримати кілька позицій швидкості обертання вентилятора, в завістімості від потреб системи.
Теплообмінник із підвищеною тепловіддачею
Підвищена тепловіддача. У блоках використовуються теплообмінники з трубками особливої конструкції, внутрішня поверхня яких має насічки трапецієподібної форми "Innergrove cooper", що забезпечує максимально збільшену площу поверхні теплообміну. Завдяки цьому тепловіддача підвищується на 28%, знижується рівень енергоспоживання і, отже, збільшується ефективність роботи системи.
Опис
- Бюджетні зовнішні блоки класу VRF;
- Оптимальне рішення для невеликих будівель;
- Велика довжина трас;
- Високоефективний компресор DC-Inverter;
- Широкий модельний ряд 20-33,5 кВт;
- G-подібний теплообмінник із гідрофільним покриттям;
- Оновлена інтелектуальна система керування;
- Вентилятори на основі двигунів DC, з покращеною аеродинамікою лопастей;
- Діапазон навантаження (за сумою індексів внутрішніх блоків) 15–130%;
- Авторестарт із відновленням робочих параметрів, із проведенням маслоповоротного циклу;
- Міцна захисна решітка вентиляторів;
- Точний контроль температури – за допомогою зміни частоти компресора та багатопозиційного EXV-клапану.