Midea "Wall Mounted MI Indoor Units M Series"

Suggested retail price

16,530- ... 23,370-hrv.

    Central Controller

    1. The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
    2. The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
    3. Users can select the desired mode and temperature with a weekly schedule.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    • M9 panel
    • Built-in EXV valve.
    • 2 directions of the output of the freon pipes and the drainage pipe - to the side (to the right to the left, if you look at the block from the front), or down.
    • New front panel design
    • Auto-relocation in V4+S / V5-X / V6 systems
    • Reduced weight of the blocks (compared to the G-S series)
    • DC fan motors provide greater energy efficiency for the entire system and reduced block noise
    • The noise level is lower by 4db compared to the G-S series
    Model MI-22G/DHN1-M MI-28G/DHN1-M MI-36G/DHN1-M MI-45G/DHN1-M
    Power supply V- Ph-Hz 220-240V~50Hz
    Cooling Capacity kW 2.2 2.8 3.6 4.5
    Input W 8 9 19 19
    Rated current A 0.27 0.31 0.43 0.44
    Heating Capacity kW 2.4 3.2 4 5
    Input W 8 9 19 19
    Rated current A 0.27 0.31 0.43 0.44
    Indoor fan motor Model WZDK20-38G WZDK20-38G ZKSP-58-8-1 ZKSP-58-8-1
    Type DC motor
    Input W 7 8 18 18
    Indoor coil Number of rows 1 2 1 2
    Tube pitch× row
    pitch
    mm 21×13.37
    Fin spacing mm 1.3
    Fin type Hydrophilic aluminum
    Piping diameter mm Ф7
    Length× height mm 585×315 585×315 701×315 701×315
    Number of circuits 2 3 3 5
    Indoor air flow (H/M/L) m3/h 422/393/356 417/370/316 656/573/488 594/507/424
    Indoor noise level (H/M/L) dB(A) 31/30/29 31/30/29 33/32/30 35/33/31
    Indoor unit Dimension (W×H×D) mm 835×280×203 835×280×203 990×315×223 990×315×223
    Packing (W×H×D) mm 935×385×320 935×385×320 1085×420×335 1085×420×335
    Net/Gross weight kg 8.4/12.1 9.5/13.1 11.4/15.5 12.8/16.9
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Design pressure (H/L) MPa 4.4/2.6
    Liquid pipe/ Gas pipe mm Ф6.35/ Ф12.7
    Connecting wiring Power wiring mm2 3×2.5
    Signal wiring mm2 3×0.75
    Drainage water pipe diameter mm Ф16.5
    Controller Wireless remote controller
    Notes:            
    Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB,  19°CWB;  outdoor temperature: 35°CDB, equivalent ref. piping: 8m (horizontal)
    Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB,  outdoor temperature: 7°CDB,  6°CWB;
    equivalent ref. piping: 8m (horizontal)          
    Model MI-56G/DHN1-M MI-71G/DHN1-M MI-80G/DHN1-M MI-90G/DHN1-M
    Power supply V- Ph-Hz 220-240V~50Hz
    Cooling Capacity kW 5.6 7.1 8 9
    Input W 27 49 53 82
    Rated current A 0.58 0.6 0.6 0.78
    Heating Capacity kW 6.3 8 9 10
    Input W 27 49 53 80
    Rated current A 0.58 0.6 0.6 0.78
    Indoor fan motor Model ZKSP-58-8-1 ZKSP-60-8-3 ZKSP-60-8-3 ZKSP-60-8-3
    Type DC motor
    Input W 25 40 40 65
    Indoor coil Number of rows 2 2 2 2
    Tube pitch× row
    pitch
    mm 21×13.37
    Fin spacing mm 1.3
    Fin type Hydrophilic aluminum
    Piping diameter mm Ф7
    Length× height mm 701×315 825×399 825×399 825×399
    Number of circuits 5
    Indoor air flow (H/M/L) m3/h 747/648/547 1195/1005/809 1195/1005/809 1421/1067/867
    Indoor noise level (H/M/L) dB(A) 38/36/34 44/39/36 44/39/36 48/43/38
    Indoor unit Dimension (W×H×D) mm 990×315×223 1194×343×262 1194×343×262 1194×343×262
    Packing (W×H×D) mm 1085×420×335 1290×375×460 1290×375×460 1290×375×460
    Net/Gross weight kg 12.8/16.9 17/22.4 17/22.4 17/22.4
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Design pressure (H/L) MPa 4.4/2.6
    Liquid pipe/ Gas pipe mm Ф9.53/ Ф15.9
    Connecting wiring Power wiring mm2 3×2.5
    Signal wiring mm2 3×0.75
    Drainage water pipe diameter mm Ф16.5
    Controller Wireless remote controller
    Notes:            
    Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB,  19°CWB;  outdoor temperature: 35°CDB, equivalent ref. piping: 8m (horizontal)
    Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB,  outdoor temperature: 7°CDB,  6°CWB;