Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Central Controller
- The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
- The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
- Users can select the desired mode and temperature with a weekly schedule.
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Turbo
Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.
Description
Specifications
Model | MI2-22GDN1 | MI2-28/GDN1 | MI2-36GDN1 | MI2-45GDN1 | ||
Power supply | 1 phase, 220-240V, 50Hz | |||||
Cooling1 | Capacity | kW | 2.2 | 2.8 | 3.6 | 4.5 |
kBtu/h | 7.5 | 9.6 | 12.3 | 15.4 | ||
Power input | W | 28 | 28 | 30 | 40 | |
Heating2 | Capacity | kW | 2.4 | 3.2 | 4.0 | 5.0 |
kBtu/h | 8.2 | 10.9 | 13.6 | 17.1 | ||
Power input | W | 28 | 28 | 30 | 40 | |
Fan motor | Model | ZKFP-20-8-6 | ZKFP-20-8-6 | ZKSP-58-8-1 | ZKSP-58-8-1 | |
Type | DC | |||||
Indoor coil | Number of rows | 1 | 2 | 1 | 2 | |
Tube pitch × row pitch | mm | 21×13.37 | ||||
Fin spacing | mm | 1.3 | ||||
Fin type | Hydrophilic aluminum | |||||
Tube OD and type | mm | Ф9.53 Inner-groove | ||||
Dimensions (L×H×W) | mm | 585×315×13.37 | 585×315×26.74 | 701×315×13.37 | 701×315×26.74 | |
Number of circuits | 2 | 3 | 3 | 5 | ||
Air flow rate3 | m3/h | 422/411/402/393/380/368/356 | 417/402/386/370/353/338/316 | 656/628/591/573/544/515/488 | 594/563/535/507/478/450/424 | |
Sound pressure level4 | dB(A) | 31/30/30/30/29/29/29 | 31/30/30/30/29/29/29 | 33/32/32/31/31/30/30 | 35/34/33/33/32/31/31 | |
Sound power level | dB(A) | 46/45/45/45/44/44/44 | 46/45/45/45/44/44/44 | 48/47/47/46/46/45/45 | 50/49/48/48/47/46/46 | |
Unit | Net dimensions5 (WxHxD) | mm | 835×280×203 | 990×315×223 | ||
Packed dimensions (WxHxD) | mm | 935×385×320 | 1085×420×335 | |||
Net/Gross weight | kg | 8.4/12.1 | 9.5/13.1 | 11.4/15.5 | 12.8/16.9 | |
Refrigerant type | R410A | |||||
Throttle | Type | Electronic expansion valve | ||||
Design pressure (H/L) | MPa | 4.4/2.6 | ||||
Pipe connections |
Liquid/Gas pipe | mm | Ф6.35/Ф12.7 | |||
Drain pipe | mm | OD Φ16 | ||||
Notes: | ||||||
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
3. Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. | ||||||
4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber. | ||||||
5. Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments. |
Model | MI2-56GDN1 | MI2-71GDN1 | MI2-80GDN1 | MI2-90GDN1 | ||
Power supply | 1 phase, 220-240V, 50Hz | |||||
Cooling1 | Capacity | kW | 5.6 | 7.1 | 8.0 | 9.0 |
kBtu/h | 19.1 | 24.2 | 27.3 | 30.7 | ||
Power input | W | 45 | 55 | 55 | 82 | |
Heating2 | Capacity | kW | 6.3 | 8.0 | 9.0 | 10.0 |
kBtu/h | 21.5 | 27.3 | 30.7 | 34.1 | ||
Power input | W | 45 | 55 | 55 | 82 | |
Fan motor | Model | ZKSP-58-8-1 | ZKSP-60-8-3 | ZKSP-60-8-3 | ZKSP-60-8-3 | |
Type | DC | |||||
Indoor coil | Number of rows | 2 | ||||
Tube pitch × row pitch | mm | 21×13.37 | ||||
Fin spacing | mm | 1.3 | ||||
Fin type | Hydrophilic aluminum | |||||
Tube OD and type | mm | Ф9.53 Inner-groove | ||||
Dimensions (L×H×W) | mm | 701×315×26.74 | 825×399×26.74 | 825×399×26.74 | 825×399×26.74 | |
Number of circuits | 5 | |||||
Air flow rate3 | m3/h | 747/713/685/648/613/578/547 | 1195/1130/1065/1005/940/875/809 | 1195/1130/1065/1005/940/875/809 | 1421/1300/1125/1067/1005/934/867 | |
Sound pressure level4 | dB(A) | 38/37/36/36/35/34/34 | 44/43/42/39/38/37/36 | 44/43/42/39/38/37/36 | 48/46/45/43/41/40/38 | |
Sound power level | dB(A) | 53/52/51/51/50/49/49 | 59/58/57/54/53/52/51 | 59/58/57/54/53/52/51 | 63/61/60/58/56/55/53 | |
Unit | Net dimensions5 (WxHxD) | mm | 990×315×223 | 1194×343×262 | ||
Packed dimensions (WxHxD) | mm | 1085×420×335 | 1290×375×460 | |||
Net/Gross weight | kg | 12.8/16.9 | 17.0/22.4 | |||
Refrigerant type | R410A | |||||
Throttle | Type | Electronic expansion valve | ||||
Design pressure (H/L) | MPa | 4.4/2.6 | ||||
Pipe connections |
Liquid/Gas pipe | mm | Ф9.53/Ф15.9 | |||
Drain pipe | mm | OD Φ16 | ||||
Notes: | ||||||
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
3. Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. | ||||||
4. Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber. | ||||||
5. Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments. |