Midea "Indoor units of wall type MI2 series"

Suggested retail price

13,680- ... 23,940-hrv.

    Central Controller

    1. The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
    2. The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
    3. Users can select the desired mode and temperature with a weekly schedule.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    • New M2 type panel wall-mounted.
    • AC fan 7-speed fan control.
    • 5-step swing louver.
    • Standard wireless remote controller
    Model MI2-22GDN1 MI2-28/GDN1 MI2-36GDN1 MI2-45GDN1
    Power supply 1 phase, 220-240V, 50Hz
    Cooling1 Capacity kW 2.2 2.8 3.6 4.5
    kBtu/h 7.5 9.6 12.3 15.4
    Power input W 28 28 30 40
    Heating2 Capacity kW 2.4 3.2 4.0 5.0
    kBtu/h 8.2 10.9 13.6 17.1
    Power input W 28 28 30 40
    Fan motor Model ZKFP-20-8-6 ZKFP-20-8-6 ZKSP-58-8-1 ZKSP-58-8-1
    Type DC
    Indoor coil Number of rows 1 2 1 2
    Tube pitch × row pitch mm 21×13.37
    Fin spacing mm 1.3
    Fin type Hydrophilic aluminum
    Tube OD and type mm Ф9.53 Inner-groove
    Dimensions (L×H×W) mm 585×315×13.37 585×315×26.74 701×315×13.37 701×315×26.74
    Number of circuits 2 3 3 5
    Air flow rate3 m3/h 422/411/402/393/380/368/356 417/402/386/370/353/338/316 656/628/591/573/544/515/488 594/563/535/507/478/450/424
    Sound pressure level4 dB(A) 31/30/30/30/29/29/29 31/30/30/30/29/29/29 33/32/32/31/31/30/30 35/34/33/33/32/31/31
    Sound power level dB(A) 46/45/45/45/44/44/44 46/45/45/45/44/44/44 48/47/47/46/46/45/45 50/49/48/48/47/46/46
    Unit Net dimensions5 (WxHxD) mm 835×280×203 990×315×223
    Packed dimensions (WxHxD) mm 935×385×320 1085×420×335
    Net/Gross weight kg 8.4/12.1 9.5/13.1 11.4/15.5 12.8/16.9
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Design pressure (H/L) MPa 4.4/2.6
    Pipe
    connections
    Liquid/Gas pipe mm Ф6.35/Ф12.7
    Drain pipe mm OD Φ16
    Notes:            
    1.     Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.  
    2.     Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.  
    3.     Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model.    
    4.     Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber.  
    5.     Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.    
    Model MI2-56GDN1 MI2-71GDN1 MI2-80GDN1 MI2-90GDN1
    Power supply 1 phase, 220-240V, 50Hz
    Cooling1 Capacity kW 5.6 7.1 8.0 9.0
    kBtu/h 19.1 24.2 27.3 30.7
    Power input W 45 55 55 82
    Heating2 Capacity kW 6.3 8.0 9.0 10.0
    kBtu/h 21.5 27.3 30.7 34.1
    Power input W 45 55 55 82
    Fan motor Model ZKSP-58-8-1 ZKSP-60-8-3 ZKSP-60-8-3 ZKSP-60-8-3
    Type DC
    Indoor coil Number of rows 2
    Tube pitch × row pitch mm 21×13.37
    Fin spacing mm 1.3
    Fin type Hydrophilic aluminum
    Tube OD and type mm Ф9.53 Inner-groove
    Dimensions (L×H×W) mm 701×315×26.74 825×399×26.74 825×399×26.74 825×399×26.74
    Number of circuits 5
    Air flow rate3 m3/h 747/713/685/648/613/578/547 1195/1130/1065/1005/940/875/809 1195/1130/1065/1005/940/875/809 1421/1300/1125/1067/1005/934/867
    Sound pressure level4 dB(A) 38/37/36/36/35/34/34 44/43/42/39/38/37/36 44/43/42/39/38/37/36 48/46/45/43/41/40/38
    Sound power level dB(A) 53/52/51/51/50/49/49 59/58/57/54/53/52/51 59/58/57/54/53/52/51 63/61/60/58/56/55/53
    Unit Net dimensions5 (WxHxD) mm 990×315×223 1194×343×262
    Packed dimensions (WxHxD) mm 1085×420×335 1290×375×460
    Net/Gross weight kg 12.8/16.9 17.0/22.4
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Design pressure (H/L) MPa 4.4/2.6
    Pipe
    connections
    Liquid/Gas pipe mm Ф9.53/Ф15.9
    Drain pipe mm OD Φ16
    Notes:            
    1.     Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.  
    2.     Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.  
    3.     Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model.    
    4.     Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber.  
    5.     Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.