Midea MSMB-18HRFN1-Q / MSMB-18HRFN1(HB) air conditioner (Archived model split systems)

Suggested retail price

0,-hrv.

Main functions

Midea AC 1W Standby feature
2-way Draining
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Cooling-Heating
Easy to clean panel
Effective drainage
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Timer
Turbo mode
High Density filter
The Ionizer filter
WiFi Module
Wired Remote Control

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 20
... + 30 °C

Mission series models are designed in 2014, power systems are made in the "universal" and modern design, familiar to most users, the development was carried out on the basis of data for the study of consumer needs around the world. Remote controller with the "revolutionary" ergonomic design, which is a manufacturer called «Arctic Fox» - include to set with indoor units. The development of forms and functional remote control and to attract the best world experts in the field of ergonomics and industrial design, display remote indicator has increased by 27% the area of ​​display graphics, system icons. Units at  Mission series are available as a split system with inverter-type compressor and capacities  9,12,18,24 Btu/h, with a special new "Diamond" design of the outdoor unit, as well as the indoor units of multi-split “Free-match” DC-inverter systems, with an capacity  9, 12, 18 Btu/h.

In addition, in a indoors of air conditioners Mission can be optionally installed Wi-Fi module for remote control and programming of operating parameters that displays the user interaction and the air conditioner to a new technological level - increases the comfort, efficiency and independence for users, provides the ability to manage "Home climate" from any point where the network is the Internet.

For order such control system, please contact your nearest dealer or service center in your area.

    Technology

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Temperature compensation

    The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.

    The Ionizer

    Air purification system is provided with a high-efficiency air conditioner ionizer that produces millions of negative ions that neutralize all the harmful elements present in your home. Negatively charged ions attract the dust particles, bacteria, mold spores and viruses, neutralize them, supporting chichtotu and freshness of the air in the room.

    The ionizer is usually located on the left side of the housing of the indoor unit under the blinds (see photo below). On some series of domestic and semi-industrial split systems, it can be installed optionally)

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    The Indoor Unit

    Model Name
    MSMB-18HRFN1-Q
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    1.900
    ... 6.180
    Heating Capacity
    1.440
    ... 6.800

    Power consumption, kW

    Cooling
    0.150
    ... 2.380
    Heating
    0.220
    ... 2.430

    Energy Efficiency Class

    Cooling
    A++
    Heating
    при +2°С=A+++. при -7°C=A+

    Energy Efficiency Ratio

    SEER (cooling mode)
    6.80
    SCOP (heating mode)
    5.40
    ... 4.20
    Air flow rate, m³/h
    725
    ... 460
    Sound Pressure Level, dB(A)
    42.00
    ... 24.00
    Sound Power Level, dB(A)
    55.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    12.70

    Dimensions(WxHxD), mm

    Without Package
    980
    x 325
    x 225
    in Multiples
    1055
    x 405
    x 305

    Weight, kg

    Net Weight
    11.00
    Gross Weight
    14.00

    The outdoor Unit

    Model Name
    MSMB-18HRFN1(HB)
    Compressors Type
    Inverter
    Compressor
    GMCC

    Freon

    Freon Type
    R-410
    Freon Weight, kg
    1.48, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    2,100
    Sound Pressure Level, dB(A)
    54.00
    Sound Power Level, dB(A)
    63.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    12.70
    Min length of main line, m
    3
    Max length of main line, m
    30
    Max vertical drop, m
    20

    Dimensions(WxHxD), mm

    Without Package
    800
    x 554
    x 333
    in Multiples
    920
    x 615
    x 390

    Weight, kg

    Net Weight
    37.00
    Gross Weight
    40.00