Midea MSMB-09HRFN1-Q ION / MSMB-09HRFN1 air conditioner (Archived model split systems)

Suggested retail price

0,-hrv.

Main functions

Midea AC 1W Standby feature
2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Cooling-Heating
Easy to clean panel
Effective drainage
Follow Me
IR Remote Control
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-cleaning function
Self-diagnosis function
Timer
Turbo mode
Carbon air filter
High Density filter
The Ionizer filter
WiFi Module
Wired Remote Control
Bio-filter
Silver Ion filter
The Vitamin C filter

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 20
... + 30 °C

Mission series models are designed in 2014, power systems are made in the "universal" and modern design, familiar to most users, the development was carried out on the basis of data for the study of consumer needs around the world. Remote controller with the "revolutionary" ergonomic design, which is a manufacturer called «Arctic Fox» - include to set with indoor units. The development of forms and functional remote control and to attract the best world experts in the field of ergonomics and industrial design, display remote indicator has increased by 27% the area of ​​display graphics, system icons. Units at  Mission series are available as a split system with inverter-type compressor and capacities  9,12,18,24 Btu/h, with a special new "Diamond" design of the outdoor unit, as well as the indoor units of multi-split “Free-match” DC-inverter systems, with an capacity  9, 12, 18 Btu/h.

In addition, in a indoors of air conditioners Mission can be optionally installed Wi-Fi module for remote control and programming of operating parameters that displays the user interaction and the air conditioner to a new technological level - increases the comfort, efficiency and independence for users, provides the ability to manage "Home climate" from any point where the network is the Internet.

For order such control system, please contact your nearest dealer or service center in your area.

    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    The Ionizer

    Air purification system is provided with a high-efficiency air conditioner ionizer that produces millions of negative ions that neutralize all the harmful elements present in your home. Negatively charged ions attract the dust particles, bacteria, mold spores and viruses, neutralize them, supporting chichtotu and freshness of the air in the room.

    The ionizer is usually located on the left side of the housing of the indoor unit under the blinds (see photo below). On some series of domestic and semi-industrial split systems, it can be installed optionally)

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Outdoor unit design "Brilliant"

    Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Maintaining temperature +8°С

    Protection against freezing of the room, maintaining the temperature of +8°C.

    The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Turbo

    Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

    Self-Cleaning

    Self-cleaning mode.

    Depending on the series of the air conditioner, this mode can be activated:

    • automatically (after a one-time activation from the remote control), each time the air conditioner is turned off (at the same time, the blinds on the indoor unit are closed, but the fan continues to work for another 10 ~ 20 minutes, ventilating and drying the heat exchanger).
    • forcibly, every time you activate it from the remote control.

    Note: Check the algorithm of the mode in the user manual.

    Follow Me

    "Follow Me" feature

    When this function is enabled on the remote control, the control unit of the indoor unit will receive data about the temperature in the room from the temperature sensor installed in the remote control, which allows you to more precisely control the operation of the air conditioner, reaching the set mode in the area where the remote control is in the room. The range of the signal from the console does not exceed 8 m. in a straight line "remote - indoor unit".

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Indoor Unit

    Model Name
    MSMB-09HRFN1-Q
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    1.170
    ... 3.310
    Heating Capacity
    0.910
    ... 3.750

    Power consumption, kW

    Cooling
    0.100
    ... 1.270
    Heating
    0.140
    ... 1.340

    Energy Efficiency Class

    Cooling
    A++
    Heating
    при +2°С=A+++. при -7°C=A+

    Energy Efficiency Ratio

    SEER (cooling mode)
    6.60
    SCOP (heating mode)
    5.10
    ... 4.00
    Air flow rate, m³/h
    500
    ... 310
    Sound Pressure Level, dB(A)
    37.00
    ... 22.00
    Sound Power Level, dB(A)
    53.00
    Drain pipes diameter, mm
    16 mm

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    9.52

    Dimensions(WxHxD), mm

    Without Package
    730
    x 293
    x 198
    in Multiples
    810
    x 375
    x 285

    Weight, kg

    Net Weight
    8.00
    Gross Weight
    10.00

    The outdoor Unit

    Model Name
    MSMB-09HRFN1(HB)
    Compressors Type
    Inverter
    Compressor
    GMCC

    Freon

    Freon Type
    R-410
    Freon Weight, kg
    0.85, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    2,100
    Sound Pressure Level, dB(A)
    54.00
    Sound Power Level, dB(A)
    61.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    9.52
    Min length of main line, m
    3
    Max length of main line, m
    25
    Max vertical drop, m
    10

    Dimensions(WxHxD), mm

    Without Package
    770
    x 555
    x 300
    in Multiples
    900
    x 585
    x 345

    Weight, kg

    Net Weight
    28.00
    Gross Weight
    30.00