Main functions
Operating ambient temperatures
Buy in one click
Models, the "Forest" series with energy-efficient (A++) DC-inverter motors, allow the system to work in winter for heating at -15°C.
The indoor unit has a glossy wave-like plastic front panel (special design Midea) with a hidden LED display, which can, if desired, turn off the indication and sound.
The outdoor units have the original design "Diamond".
Energy Efficiency
Technology
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Eco mode
Economy mode(Eco-mode).Conditioning supports indoor air temperature +24°C with minimum noise and power consumption.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Turbo
Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.
Self-Cleaning
Self-cleaning mode.
Depending on the series of the air conditioner, this mode can be activated:
- automatically (after a one-time activation from the remote control), each time the air conditioner is turned off (at the same time, the blinds on the indoor unit are closed, but the fan continues to work for another 10 ~ 20 minutes, ventilating and drying the heat exchanger).
- forcibly, every time you activate it from the remote control.
Note: Check the algorithm of the mode in the user manual.
Temperature compensation
The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.