Midea "UNIVERSAL OUTDOOR UNITS"

Operating ambient temperatures

Cooling mode
+ 18
... + 43 °C
Heating mode
- 7
... + 24 °C

Suggested retail price

29,400- ... 39,480-hrv.
    ModelMOU2-24HN1-QMOU1-36HN1-R
    Power supplyV,Hz,Ph220~240,50,1380~415,50,3
    Max. input consumption       W37004250
    Max. input current             A187
    Starting current               A54.936 
    CompressorModel  KTG275V2VMPATQ420Y1TMT
    Type  ROTARYROTARY
    Brand  GMCCGMCC
    Refrigerant oil   mlESTER OIL VG74  750mlESTER OIL VG74 1200CC
    Outdoor fan motorModel  YKT-65-6-240LYKS-190-6-21L
    Qty  11
    InputW135 293
    CapacitorμF510,0
    Speed       r/min825850/770
    Outdoor coilNumber of rows 1.62.0
    Tube pitch(a)* row pitch(b) mm21x13.3725.4x22
    Fin spacingmm1.31.3 
    Fin type  Hydrophilic aluminium(Golden)Hydrophilic aluminium(Golden)
    Tube outside dia.and type mmФ7,Inner groove tubeΦ9.52,innergroove tube
    Coil length * height * widthmm900x26.74x609995x762x44
    Number of circuits 54
    Outdoor noise level (sound pressure)   dB(A)6062.5
    Outdoor air flowm3/h36503800
    Throttle type Throttle ValveThrottle valve
    Outdoor unitDimension(WxDxH)mm890x342x673946x410x810
    Packing(WxDxH)mm995x398x7401090x500x875
    Net/Gross weight kg53.9/5773.0/77.5
    Refrigerant type/Quantity Type R410AR410A
    Charged volumekg1.82,85
    Refrigerant pipingLiquid side/ Gas side mm(inch)9.52mm(3/8in)/15.9mm(5/8in)9.52mm(3/8in)/19mm(3/4in)
    Max. pipe length   m2530
    Max. difference in levelm1520
    Ambient temperatureCooling18-43-15-43 (LAK standard*)
    Heating-7-24-7-24
    Remarks:1. Вищезазначений дизайн та технічні характеристики можуть бути змінені без попереднього повідомлення з метою вдосконалення продукту.                            
     2. *LAK standard - плата регулятор оборотів дв.вентилятора нар блоку дозволяють до -15С вулиці працювати системі в режимі "Охолодження"

    Golden Fin

    Gold plating fin heat exchanger - Corrosion protection. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment.

    Crankcase Heater

    To prevent the compressor's hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    • The same outdoor units are used for split systems with the same capacity

    • 3-wire control (220V)

    • Separate power supply for indoor and outdoor units is allowed

    • High-efficiency compressors

    • Housing panels made of galvanized steel according to class G90