Midea MCD(1) DC MCD-24HRDN1-Q /MOU-24HDN1-Q (2019) air conditioner

Suggested retail price

74 100,-hrv.

Main functions

24-hour timer
3-minute protection feature
Air outlet in all directions
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Built-in drain pump
Cooling-Heating
Effective drainage
Fresh Air
IR Remote Control
LED display
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Small height of the housing
The central group control panel
WiFi Module
Wired Remote Control
Ionizer

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 24 °C

The cassette conditioner of the MCD series belongs to devices of industrial and semi-industrial classes and is intended to maintain the set parameters of air in large areas:

  • trading rooms;
  • catering establishments;
  • exhibition complexes and galleries;
  • workshops and workshops.

The evaporator of the internal “cassette” unit is located along the perimeter of the outer panel of the square case, which allows the fan to drive cold air in four directions simultaneously. Due to this, the unit installed in the false ceiling in the center of a room is able to “cover” a much larger area at once than a regular wall unit.

In order to install the indoor unit of a cassette air conditioner, a suspended ceiling and sufficient space between the suspended ceiling and the solid ceiling are required.

    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    The Indoor Unit

    Model Name
    MCD-24HRDN1-Q
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    2.110
    ... 8.440
    Heating Capacity
    2.290
    ... 9.140

    Power consumption, kW

    Cooling
    0.690
    ... 3.180
    Heating
    0.560
    ... 2.970
    Air flow rate, m³/h
    1,250
    ... 900
    Sound Pressure Level, dB(A)
    51.00
    ... 38.00
    Drain pipes diameter, mm
    32 mm

    Diameter Pipes, mm

    Liquid
    9.52
    Gas
    16.00

    Panel

    Panels Colour
    White
    Panel Size (WxHxD), mm
    950
    x 55
    x 950
    Panel Weight, kg
    5.00

    Dimensions(WxHxD), mm

    Without Package
    840
    x 205
    x 840
    in Multiples
    900
    x 217
    x 900

    Weight, kg

    Net Weight
    22.00
    Gross Weight
    25.00

    The outdoor Unit

    Model Name
    MOU-24HDN1-Q
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY

    Freon

    Freon Type
    R410A
    Freon Weight, kg
    2.10, kg
    Power Options, V/Hz/Ph
    220/50/1
    Sound Pressure Level, dB(A)
    62.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    16.00
    Min length of main line, m
    3
    Max length of main line, m
    25
    Max vertical drop, m
    15

    Dimensions(WxHxD), mm

    Without Package
    845
    x 702
    x 363
    in Multiples
    965
    x 755
    x 395

    Weight, kg

    Net Weight
    46.00
    Gross Weight
    49.00