Midea "M4OB-36HFN1-Q" series

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 24 °C

Suggested retail price

75,620-hrv.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Outdoor unit design "Brilliant"

    Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    A wide range of indoor units by type and performance.

    Up to 5 indoor units of various types (wall, cassette 600х600, channel and floor-ceiling) can be connected to multisystems.
    Simultaneously, the units can operate only in one mode - cooling or heating, but in each room it is possible to set and maintain individual air parameters. DC inverter control of the compressor motor and outdoor fan provides high energy efficiency and economy of the system.

    Possible combinations of indoor units for outdoor multisystem units.
    This series of multi-split systems is assembled as a "designer" - i.e. Different internal units are connected to one outdoor unit in certain combinations by power indices, while the type and design of indoor units is not limited and is chosen according to the client's desire.
    The combinations of the connected indoor units can only be performed in accordance with the tables given.

    Outdoor ModelM4OB-36HFN1-Q
    Outdoor Model NEWM4O-36FN1-Q
    Indoor unit combinationSingleDoubleThreeMA-09N1D0-I
    MSMAAU-09HRDN1
    Power supplyV,Hz, Ph220-240V,50Hz, 1Ph
    CoolingCapacity                     Btu/h7000-1800014000-2600021000-3600036000
    Input           W1250-17001650-23202150-35203893
    Rated current   A5.4-7.47.2-10.19.3-15.316,9
    HeatingCapacity        Btu/h8000-2000016000-2900024000-3800038000
    Input           W1375-24402050-33402880-33603000
    Rated current   A5.9-10.68.9-14.512.5-14.613
    Seasonal CoolingPdesignckW10.6
    SEERW/W7,6
    Energy Efficiency Class A++
    Heating(Average)PdesignhkW9.3
    SCOPW/W3,8
    Energy Efficiency Class A
    Tbiv-7
    Tol-15
    Max. input consumption        W4600
    Max. input current             A21.5
    CompressorModel  ATF310D43UMT
    Type  ROTARY
    Brand  GMCC
    Capacity     Btu/h32380
    Input          W2600
    Rated current(RLA) A5,1
    Thermal protector position INTERNAL
    Refrigerant oil   mlPQE(VG74)/1000
    Outdoor fan motorNew Model  ZKFN-120-8-2
    Model  WZDK120-38G-W
    Qty  1
    OutputW120(Output)
    Speed(Hi/Med/Lo)r/min900
    Outdoor coilNumber of rows 2
    Tube pitch(a)* row pitch(b) mm25.4x22
    Fin spacingmm1.3
    Fin type  Hydrophilic aluminium
    Tube outside dia.and type mmФ9.52, innergroove tube
    Coil length * height * widthmm995x762x44
    Number of circuits 4
    Outdoor air flow            m3/h5500
    Indoor sound power level dB(A)54
    Outdoor  sound pressure leveldB(A)63.5
    Outdoor sound power level dB(A)68
    Throttle type Capillary+EXV
    Outdoor unitDimension(WxDxH)mm946x410x810
    Packing(WxDxH)mm1090x500x875
    Net/Gross weight  kg70/75
    Refrigerant          Type  R410A
    GWP 2088
    Charged quantityKg3
    Design pressureMPa4.2/1.5
    Refrigerant pipingLiquid side/ Gas side  mm (inch)4 x Φ6.35/3x Φ9.52+1xΦ12.7(4x1/4"/3x3/8"+1x1/2")
    Max. length for all roomsm80
    Max. length for one indoor unitm35
    Max. height difference between indoor & outdoor unit m15
    Max. height difference between indoor units m10
    Ambient temperatureCooling-15-50
    Heating-15-24
    Remarks:                  
    1.The above design and specifications are subject to change without prior notice for product improvement.      
    2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms.