Midea "Indoor unit MDV floor and ceiling type MI2, DLDHN1 series"

Suggested retail price

36,100- ... 62,130-hrv.

    Central Controller

    1. The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
    2. The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
    3. Users can select the desired mode and temperature with a weekly schedule.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Wide angle air flow

    The vertical louvers of Midea air conditioners swing at an angle of 110° (ordinary air conditioners only swing at 80°), while the horizontal louvers swing at 120° (ordinary air conditioners only swing at 90°). These more flexible louvers provide cooling which is wider and more even.

    Indoor units of the floor-ceiling type of the 2nd generation of the MI2-DLDHN1 series are presented by models with a power from 3,6 to 14,0 kW. The devices can be installed in a horizontal position, mounted to the ceiling or in a vertical position, attached to the wall or floor. Models of this series are delivered without the control panel which need to be got separately.

    Features of the series:

    •     DC Inverter fan motor
    •     Horizontal or vertical installation
    •     Air distribution in 4 directions
    •     High performance
    •     Built-in EXV valve
    •     Automatic horizontal and vertical blinds
    •     Automatic operation of air dampers
    •     Drainage pump (optional)
    •     Control panel (optional)
    Model MI2-36DLDHN1 MI2-45DLDHN1 MI2-56DLDHN1 MI2-71DLDHN1
    Power supply 1 phase, 220-240V, 50/60Hz
    Cooling1 Capacity kW 3.6 4.5 5.6 7.1
    kBtu/h 12.3 15.4 19.1 24.2
    Power input W 49 115 115 115
    Heating2 Capacity kW 4.0 5.0 6.3 8.0
    kBtu/h 13.6 17.1 21.5 27.3
    Power input W 49 115 115 115
    Fan motor Model WZDK100-38GS-2
    Type DC
    Brand Panasonic/Match-Well
    Speed3 r/min 770/740/700/680/650/630/610 1380/1330/1300/1260/1210/1140/1070 1380/1340/1300/1260/1190/1140/1120
    Indoor coil Number of rows 2 3 3 3
    Tube pitch × row pitch mm 25.4×22
    Fin spacing mm 1.8
    Fin type Hydrophilic aluminum
    Tube OD and type mm Ф9.52 Inner-groove
    Dimensions (L×H×W) mm 804×254×44 804×254×66 804×254×66
    Number of circuits 3
    Air flow rate3 m3/h 550/525/500/480/460/440/420 930/895/860/830/792/755/720
    Sound pressure level4 dB(A) 40/39/38/38/37/36/36 43/42/41/41/39/38/38
    Unit Net dimensions5 (WxHxD) mm 990×660×203
    Packed dimensions (WxHxD) mm 1089×744×296
    Net/Gross weight kg 26/32 28/34
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Model D20MISZ-1R(L)
    Design pressure (H/L) MPa 4.4/2.6
    Pipe
    connections
    Liquid/Gas pipe mm Ф6.35/Ф12.7 Ф9.53/Ф15.9
    Drain pipe mm OD Φ16
    Notes:            
    1.     Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.  
    2.     Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.  
    3.     Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model.    
    4.     Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber.  
    5.     Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.    
    Model MI2-80DLDHN1 MI2-90DLDHN1 MI2-112DLDHN1 MI2-140DLDHN1
    Power supply 1 phase, 220-240V, 50/60Hz
    Cooling1 Capacity kW 8.0 9.0 11.2 14.0
    kBtu/h 27.2 30.7 38.2 47.8
    Power input W 130 130 180 180
    Heating2 Capacity kW 9.0 10.0 12.5 15.0
    kBtu/h 30.7 34.1 42.7 51.2
    Power input W 130 130 180 180
    Fan motor Model WZDK100-38GS-1 WZDK100-38GS-2
    Type DC DC
    Brand Panasonic/Match-Well
    Speed3 r/min 1300/1270/1230/1200/1160/1120/1090 1140/1090/1060/1040/1010/990/970
    Indoor coil Number of rows 3
    Tube pitch × row pitch mm 25.4×22
    Fin spacing mm 1.8
    Fin type Hydrophilic aluminum
    Tube OD and type mm Ф9.52 Inner-groove
    Dimensions (L×H×W) mm 1094×254×66 1360×254×66
    Number of circuits 5
    Air flow rate3 m3/h 1280/1245/1210/1170/1130/1085/1050 1890/1830/1765/1700/1660/1620/1580
    Sound pressure level4 dB(A) 45/44/43/43/42/41/40 47/46/45/45/44/43/42
    Unit Net dimensions5
    (WxHxD)
    mm 1280×660×203 1670×680×244
    Packed dimensions
    (WxHxD)
    mm 1379×744×296 1915×760×330
    Net/Gross weight kg 35/41 48/58
    Refrigerant type R410A
    Throttle Type Electronic expansion valve
    Model BD24FKS(L)
    Design pressure (H/L) MPa 4.4/2.6
    Pipe
    connections
    Liquid/Gas pipe mm Ф9.53/Ф15.9
    Drain pipe mm OD Φ16
    Notes:            
    1.     Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
    2.     Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
    3.     Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model.  
    4.     Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber.
    5.     Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.